Acson Air Conditioner User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 7
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
More quiet room environment.
With up to five selectable fan speeds, users are given
more choices. By selecting Quiet mode, the sound
pressure level is reduced down to an unobtrusive 21dBA.
To quickly cool down the room, Turbo Mode can be
selected for maximum cooling power and highest airflow.
series
Wall Mounted
NEW
Inverter
6 7
A5WMY 20/25JR
Cooling Capacity (kW) : 5.4 - 6.2
Heating Capacity (kW) : 5.6 - 6.4
A5WMY 10/15LR
Cooling Capacity (kW) : 2.5 – 3.3
Heating Capacity (kW) : 2.8 – 3.5
Power Failure Power Failure
E
2
PROME
2
PROM
Operation Stop
Restart
Setting stored before power failure.
Protection 2
Micron-scale fibers trap dust while titanium apatite adsorbs organic contaminants such as bacteria and viruses. In addition,
the titanium oxide is activated by natural light, allowing it to break down and eliminate odours. The filter effectively
deactivates bacteria and viruses. It lasts for three years without replacement if washed about once every six months.
Absorption of dangerous airbone particles like dust, pollen
and cigarette smoke.
Dissolves odor, bacteria and virus.
Photo catalytic deodorizing filter
Mechanism of photo catalytic.
- Titanium Oxide is activated by exposure to light.
- Becomes highly oxidative.
- Dissolves absorbed sunstances into harmless water (H
2
O)
and carbon dioxide (CO
2
).
Natural
Sunlight
Step 1 Step 2 Step 3
When photocatalyst is exposed to light, it
is activated and absorbs odor particles
A chemical reaction decomposes the
odors into CO
2 and H2O
The odorless substances and then
released into the air.
Protection 1
Bio-Pro is an IAQ solution which combines superior cleansing and purifying of Bio Antibody filter with more effective
deodorizing features of Titanium Apatite filter.
Working in tandem, both technologically-advanced air filters offer higher level of IAQ and room comfort.
*Bio-Pro is offered as optional accessories.
Ideal blend of style and function.
The front panel is designed for contemporary style without compromising on function.
Air intake area is designed to ensure smooth air flow profile for better sound quality and optimized air flow volume.
In the event of a sudden power failure during operation, unit can be automatically
restarted in 64 different recovery timing patterns and the unit will operate base on
the previous setting (Operating Mode, Temperature Setting and Fan Speed).
This ensures that air conditioners in the same building resume randomly instead
of all at the same time, preventing power surges after a blackout.
20
Rustling
Of Leaves
30
Pendulum Of
A Wall Clock
40
Library
50
Normal Office
(dB)
21dBA
for
A5WMY10LR
21dBA Is So Quiet You Can Even Hear Whispers
Fan
Speed
H
Low High
SL L
M
Turbo
INDOOR MODEL A5WMY10LR A5WMY15LR A5WMY20JR
A5WMY25JR
OUTDOOR MODEL A5LCY10FR A5LCY15FR A5LCY20CR
A5LCY25CR
W 2550 (1300~3000) 3300 (1300~3800) 5450 (1880~6200)
6210 (2000~6500)
Btu/h 8700 (4400~10200) 11300 (4400~13000) 18600 (6415~21155)
21200 (6824~22178)
W 2800 (1300~4000) 3500 (1300~48000) 5620 (1320~6600)
6400 (1560~7100)
Btu/h 9600 (4400~13600) 11900 (4400~16400) 19176 (4504~22520)
21837 (5323~24226)
EER W/W 3.43 3.37 3.73
3.30
COP W/W 4.06 3.76 3.75
3.74
( V / Ph / Hz )
dBA 21/40 22/41 33/41
34/44
CFM (l/s) 324 (153) 337 (160) 529 (250)
654 (309)
HEIGHT mm
WIDTH mm
DEPTH mm
kg
TYPE
dBA 46 48
HEIGHT mm
WIDTH mm
DEPTH mm
kg 27 29
PRE-CHARGED m
MAXIMUM m
LIQUID mm (in) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
6.35 (1/4)
GAS mm (in) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2)
15.9 (5/8)
COOLING °C DB
HEATING °C WB
ENERGY EFFICIENCY
OUTDOOR UNIT
POWER SUPPLY
SOUND LEVEL (MINIMUM/MAXIMUM)
PIPE LENGTH
HEAT PUMP MODEL
AIR FLOW RATE
UNIT
DIMENSIONS
INDOOR UNIT
COOLING
HEATING
RATED CAPACITY
(MINIMUM~MAXIMUM)
OPERATING RANGE
(MINIMUM ~ MAXIMUM)
PIPE CONNECTION SIZE
-15 ~ 18
REFRIGERANT
-10 ~ 46
753
30 30
UNIT WEIGHT
855
49 49
UNIT
DIMENSIONS
SOUND LEVEL
288
800
204
9
550
658
289
UNIT WEIGHT
-15 ~ 20
51
224
345
15 15
14
7.5 7.5 7.5 7.5
220 - 240 / 1 / 50
R410A (ZERO OZONE-DEPLETION POTENTIAL)
10 ~ 46
310
1065
Single-Split Y-Inverter Wall-Mounted Series
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) & ISO 13253 (DUCTED PRODUCT)
3) COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN ANECHOIC CHAMBER ACCORDING TO JIS C 9612 STANDARD.
IgY Antibody
Bio-Antibody Filter
Special filter material that
contains IgY antibodies
Deactivates 99.99% of airborne
infections viruses within 1 minit
Deactivated even if it
becomes airborne again
Free floating viruses and
antigen causes potential
health hazards and
discomfort to the room
occupants.
Airborne Virus
No longer harmful to room occupants.
Air is fresher.
Bio-engineering is the fusion of life science with engineering
principles that creates exciting new solutions to considerably
enhance the needs of modern lifestyle.
Using advanced bio-engineering techniques, the Bio
Antibody filter is able to eliminate up to 99.99%* of various
airborne infectious viruses to provide a cleaner and more
purified living environment.
Page view 4
1 2 3 4 5 6 7

Comments to this Manuals

No comments