Conventional
Air Conditioner
• High starting current
• Frequent on/off cycle
Inverter Air Conditioner
• Low starting current
• Smooth operation
Running Current
Hours of operation
Precise & Stable Temperature Control
Room
Temperature
Set
Temperature
Time
Fast Cooling
Set
Temperature
Room
Temperature
Time
Conventional SystemInverter System
Soft-start feature.
High current draw during startup is avoided due to the
smooth ramp-up profile of inverter compressor.
Rapid response time.
After quickly reaching Set Temperature, the inverter system constantly adjusts and fine-tunes the
cooling/ heating capacity to prevent undesired temperature swings.
Room comfort level is constantly maintained even when the number of people in the room increases or
decreases.
Acson offers wide selection of indoor models suitable for any type of interior types demand, from the
popular Wall Mounted to the more refined Ceiling Cassette models.
Acson’s range of inverter products also fulfills cooling and heating requirements from 2.5 kW up to 17.5 kW
.
This ensures the benefits of inverter technology can be applied to most requirements.
Loss
Loss
Set
Temperature
Loss
Loss
50%
Inverter Y Series
Non-Inverter
9.51kWh
4.83kWh
4 5
Superior Comfort • Powerful Operation
Higher Efficiency • Better Energy Savings
While fixed speed (non-inverter) systems operates by compressor start-stop cycles, this consumes much more
energy and room temperature variance is higher.
Inverter air-conditioning technology is today’s solution for superior comfort, higher efficiency and better
energy-savings. Acson’s inverter technology lowered energy consumption up to 50% and its powerful action allows
you to reach the desired temperature quickly and maintains precise temperature to ensure consistent level of comfort.
By using intelligent controls, compressor
running speed is matched with air-conditioning
load. This achieves significant savings in
energy consumption.
Cummulative Power Consumption
* Comparison between 1.5hp Inverter and
Non-Inverter when operating 8 hours a day.
* Subject to individual operating conditions.
Test Conditions:
1. Room size: 16.5m
2
(area)
2. Set Temperature: 25 degC
3. Outside Temperature: 33 degC DB
4. Fan speed: High
5. Air flow: Maximum air flow
The extended piping length promote flexible installation.
A5LCY10DR
7.5 15.0 10.0
A5LCY10FR 7.5 15.0 10.0
A5LCY15DR 7.5 15.0 10.0
7.5 15.0 10.0
A5LCY20CR 7.5 30.0 10.0
A5LCY25CR 7.5 30.0 10.0
A5LCY28CR 7.5 50.0 30.0
A5LCY40FR 30.0 75.0 30.0
A5LCY50FR 30.0 75.0 30.0
A5LCY60FR 30.0
75.0
30.0
A5LCY15FR
Model Pre-Charge Length (m) Maximum Length (m) Maximum Height (m)
Note:
Additional refrigerant is required if the piping is longer than the pre-charge length. For details, kindly refer to the installation manual.