Acson G6 Troubleshooting Guide

Browse online or download Troubleshooting Guide for Remote controls Acson G6. Acson G6 Troubleshooting guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - GUIDE BOOK

SERVICEGUIDE BOOK

Page 2 - Table of Contents

ASCON Service Guide Book Handset Oper

Page 3 - 1.0 MODEL NAME

ASCON Service Guide Book Handset Oper

Page 4 - 2.0 CONVERSION TABLE

ASCON Service Guide Book Handset Oper

Page 5 - Netware 3C

ASCON Service Guide Book Handset Oper

Page 6

ASCON Service Guide Book Handset Oper

Page 7 - 4.0 HANDSET OPERATING GUIDE

ASCON Service Guide Book Handset Oper

Page 8 - Operation Guide

ASCON Service Guide Book Handset Oper

Page 9 - 4.3 G12

ASCON Service Guide Book Handset Oper

Page 10 - 4.4 G18

ASCON Service Guide Book Handset Oper

Page 11 - 4.5 GS02

ASCON Service Guide Book Handset Oper

Page 12

ACSON Service Guide Book Table of Contents 1 Table of Contents 1.0 MODEL NAME 1.1 Product Name Description ...

Page 13 - 4.6 APJ2

ASCON Service Guide Book Handset Oper

Page 14

ASCON Service Guide Book Handset Oper

Page 15 - 4.7 SLM3

ASCON Service Guide Book Handset Oper

Page 16 - 4.8 SLM9

ASCON Service Guide Book Handset Oper

Page 17

ASCON Service Guide Book Handset Oper

Page 18 - 4.8 Sequential Controller

ASCON Service Guide Book Handset Oper

Page 19 - 4.9 Netware 3 / Netware 3C

ASCON Service Guide Book Handset Oper

Page 20

ASCON Service Guide Book Controller Configuration 26 5.0 CONTROLLER SETTING 5.1 Auto Random Restart 5.2 Hot Keep Selection • Shorted a

Page 21 - 4.10 Rooftop Panel

ASCON Service Guide Book Controller Configuration 27 L2 Models Two selections are available: a. Fan ON: - If the indoor coil temperat

Page 22 - 4.11 Chiller Panel

ASCON Service Guide Book Controller Configuration 28 5.3 Sequential Board (SQ2.0) Dip switch setting of sequential controller are as the f

Page 23 - 4.12 MC301

ACSON Service Guide Book Model Name 2 1.0 MODEL NAME 1.1 Product Name Description No. Description Generic Model Name ACSON B

Page 24

ASCON Service Guide Book Controller Configuration 29 6. Defrost Option Select whether compressor will turn off or remain on when 4WV chang

Page 25 - 4.13 MC303

ASCON Service Guide Book Controller Configuration 30 5.4 Chilled Water Fan Coil Unit (W1V3) The standard W1V3 board comes with a VALVE jum

Page 26

ASCON Service Guide Book Controller Configuration 31 5.5 Chilled Water Fan Coil Unit (W2.0) The system operating modes can be configured

Page 27 - 5.0 CONTROLLER SETTING

ASCON Service Guide Book Controller Configuration 32 5.6 Hardware Setting – SLM9 There are 2 jumpers on SLM9 option to control the board f

Page 28 - L208A / LWS2.0 models

ASCON Service Guide Book Controller Configuration 33 6.0 CONVERSION CONFIGURATION 6.1 Auxiliary Heater Conversion U1.5 Heatpump with Auxi

Page 29 - 5.3 Sequential Board (SQ2.0)

ASCON Service Guide Book Controller Configuration 34 SB125 Heatpump with Auxiliary Heater To convert SB125 heatpump PCB to auxiliary heate

Page 30

ASCON Service Guide Book Controller Configuration 35 W2 Heatpump with Auxiliary heater To convert SB125 heatpump PCB to auxiliary heater a

Page 31

ASCON Service Guide Book Controller Configuration 36 6.2 Multi Split Conversion Cooling Only Model (L2.0 / L208A) AWM-G, ACK-A/B/C/E, ACM

Page 32

ASCON Service Guide Book Controller Configuration 37 6.3 U1.5 Æ L208A Conversion All single split indoor units with U1.5 PCB cannot be dir

Page 33

ASCON Service Guide Book Controller Configuration 38 6.4 WMF U1.4 to L2EF Conversion 1. The U1.4 PCB can be replaced directly by the new

Page 34 - 6.0 CONVERSION CONFIGURATION

ACSON Service Guide Book Conversion Table 3 2.0 CONVERSION TABLE 2.1 Conversion Table Capacity Btu/hr MBH kCal/Hr kW 1 0.001 0

Page 35

ASCON Service Guide Book Controller Configuration 39 6.5 SQ Board for Wiring up to 1000m Conversion Comparison of Sequential Main Board SQ

Page 36 - 2. JM Relay 240VAC/ 20A

ASCON Service Guide Book Controller Configuration 40 Sequential LCD conversion for wiring up to 1000m Work Indication (WI): Step 1: Disma

Page 37 - 6.2 Multi Split Conversion

ASCON Service Guide Book Controller Configuration 41 6.6 Room Sensor on Netware 3 There is a temperature sensor located at TH1 on the Net

Page 38 - U1.5 Æ L208A Conversion

ASCON Service Guide Book Diagnosis 42 7.0 SERVICE DIAGNOSIS 7.1 LED Lights Diagnosis Table Wall Mounted F Series Cooling Only Model

Page 39

ASCON Service Guide Book Diagnosis 43 Wall Mounted F Series Heat Pump Model Board Handset AWM 10/15/20/25FR, 301R U1.5 G8 / SLM3 /

Page 40 - IC:MAX1483

ASCON Service Guide Book Diagnosis 44 Wall Mounted G Series Model Board Handset AWM 10/15/20/25G/GR L2.2 G18 / SLM3 / Netware 3 /

Page 41

ASCON Service Guide Book Diagnosis 45 Wall Mounted J Series Model Board Handset AWM 09/15J/JR L2GSN G18 SLEEP (Red) POWER (

Page 42 - 6.6 Room Sensor on Netware 3

ASCON Service Guide Book Diagnosis 46 Ceiling Cassette A / B / C Series Model Model Board Handset ACK 20/25/30/40/50A/AR U1.5 G8 / S

Page 43 - Twice every 2s

ASCON Service Guide Book Diagnosis 47 Ceiling Cassette A / B / C/ E Series Model Model Board Handset ACK 20/25/30/40/50A/AR L208A G18

Page 44 - (Green)

ASCON Service Guide Book Diagnosis 48 Ceiling Exposed D Series Model Model Board Handset RCM 20/25/30/40/50D/DR U1.5 G8 / SLM3 / Ne

Page 45 - Wall Mounted G Series

ASCON Service Guide Book

Page 46 - Wall Mounted J Series

ASCON Service Guide Book Diagnosis 49 Ceiling Exposed D / E Series Model Model Board Handset RCM 20/25/30/40/50D/DR L208A G18 / SL

Page 47

ASCON Service Guide Book Diagnosis 50 Chilled Water Fan Coil Unit Model Board Handset AWM 05 – 25FW, 301W W1V3 G8 / SLM3 / Netware

Page 48

ASCON Service Guide Book Diagnosis 51 Water Source Split Unit – Wall Mounted G Series Model Model Board Handset A5WMWS 10/15/20/25GR

Page 49

ASCON Service Guide Book Diagnosis 52 Water Source Split Unit – Ceiling Cassette A / B / C Series Model Model Board Handset A5CKWS 2

Page 50

ASCON Service Guide Book Diagnosis 53 Wall Mounted F Cooling Only Inverter-X Model Model Board Handset AWMX 10/15F VA2.0 G18 / SLM3

Page 51 - Chilled Water Fan Coil Unit

ASCON Service Guide Book Diagnosis 54 Wall Mounted F Heatpump Inverter-X Model Model Board Handset AWMX 10/15FR VA2.0 G18 / SLM3

Page 52

ASCON Service Guide Book Diagnosis 55 Wall Mounted G Series Inverter-X Model Model Board Handset AWMX 10/15/20/25G/GR VA2.0 G18

Page 53 - Series Model

ASCON Service Guide Book Diagnosis 56 Ceiling Cassette A/C Series Inverter-X Model Model Board Handset ACKX 20/25A/AR VA3.0 G18 /

Page 54

ASCON Service Guide Book Diagnosis 57 Ceiling Convertible E Series Inverter-X Model Model Board Handset ACMX 15/20/25E/ER VA3.0 G1

Page 55

ASCON Service Guide Book Diagnosis 58 Inverter - X Outdoor Unit Model Board ALCX 10/15/20/25C/CR VB2.0 AMSV 25/35A VB2.0 AMSX 20/25

Page 56 - (Orange)

ASCON Service Guide Book

Page 57

ASCON Service Guide Book Diagnosis 59 Inverter-Y Model Indoor Series Model Board Handset A5WMY 10/15/20/25 JR W_2_03A GS02 / G18

Page 58 - 6 times

ASCON Service Guide Book Diagnosis 60 Single Split Inverter – Y Outdoor Unit Model Board A5LCY 10/15 DR S_2_03A A5LCY 20/25 CR S_

Page 59 - Inverter - X Outdoor Unit

ASCON Service Guide Book Diagnosis 61 Multi Split Inverter – Y Outdoor Unit Model Board A5MSY 20/25/30 BR - The outdoor unit LED

Page 60

ASCON Service Guide Book Diagnosis 62 7.2 Error Codes Diagnosis By Handset SLM 3 / Netware 3 / SLM 9 – On/Off Models Error Code Fau

Page 61

ASCON Service Guide Book Diagnosis 63 Netware 3C / SLM 9 – Inverter Y Models (Except 5WMY-J/JR) Error Code Faulty Indication Error Cod

Page 62

ASCON Service Guide Book Diagnosis 64 Sequential Controller (SQ LCD) – SB & RT Multi Compressors Error Code Faulty Indication Erro

Page 63 - SLM 3 – Inverter X Models

ASCON Service Guide Book Diagnosis 65 Rooftop Panel Alarm Shown On The Rooftop Panel • Whenever panel received a new alarm, an alarm m

Page 64 - 5WMY-J/JR)

ASCON Service Guide Book Diagnosis 66 Condenser fan motor faulty Replace fan motor. Main PCB faulty Replace main PCB. 9. Disconnection

Page 65 - Compressors

ASCON Service Guide Book Diagnosis 67 Chiller Panel – Air Cooled Mini Chiller When malfunctioning occurred, the display LCD will blink

Page 66 - Rooftop Panel

ASCON Service Guide Book Diagnosis 68 G18 – Inverter Y Models Diagnosis Step 1. Hold down TIMER CANCEL button for 5 seconds, a “

Page 67

ASCON Service Guide Book Handset Ope

Page 68

ASCON Service Guide Book Diagnosis 69 GS02 – Inverter Y Models Diagnosis Step 1. Hold down ON TIMER CANCEL button or OFF TIMER C

Page 69 - G18 – Inverter Y Models

ASCON Service Guide Book Diagnosis 70 Error Codes for G18 and GS02 – Inverter Y Models Error Codes Error Descrip

Page 70 - GS02 – Inverter Y Models

ASCON Service Guide Book Diagnosis 71 APJ2 –A5WMY10/15KR Indoor LED Indication The operation lamp (green) flashes when any of t

Page 71

ASCON Service Guide Book Diagnosis 72 7.3 MDS Diagnosis (A)Indoor Units Model Board Handset A(5)WMD 09/10/15/20/25 G MC201-C G18

Page 72 - APJ2 –A5WMY10/15KR

ASCON Service Guide Book Diagnosis 73 Error Diagnosis by Wired Controller (MC301) ITEM CODE DESCRIPTION 18 F3 Sensor Broken (indoor

Page 73 - (A)Indoor Units

ASCON Service Guide Book Diagnosis 74 (B) Outdoor Units Model Board Handset AMDS 30/40/50/60/70 A/AR V4.0 – V4.5 G18/ MC301 AMDS 80

Page 74

ASCON Service Guide Book Diagnosis 75 7.4 General Check When any air conditioner malfunction is noted, immediately switch off the powe

Page 75 - (B) Outdoor Units

ASCON Service Guide Book Diagnosis 76 7.5 General Troubleshooting Guide By means of pressure readings: Pressure Probable Cause Too L

Page 76 - 7.4 General Check

ASCON Service Guide Book Appendix 77 APPENDIX A. Resistance – Temperature Characteristics Model ALL ON/OFF UNIT, FAN COIL UNIT R

Page 77

ASCON Service Guide Book Appendix 78 Model A5WMY10/15KR; A5LCY10/15ER; A5LCY30/40/50/60FR Resistance R25=20.0kΩ + 1.0% - 1.0%

Page 78 - APPENDIX

ASCON Service Guide Book Handset Oper

Page 79

ASCON Service Guide Book Appendix 79 Model A5LCY30/40/50/60FR Discharge Pipe Sensor Resistance R25=230.0kΩ + 1.0% - 1.0% T°C R

Page 80

ASCON Service Guide Book Appendix 80 B. MDS Compatibility Indoor PCB vs Wired Handset MC301 MC301 Indoor PCB B1.5 B1.6 B.17 B1.8

Page 81 - B. MDS Compatibility

ASCON Service Guide Book Appendix 81 C. MDS Outdoor Capacity Dip Switch Setting MDS-B PCB version 2.3 and below: Dip Switch S3.1 S3.2

Page 82

ASCON Service Guide Book Appendix 82 D. Cable Length of Wired Handset No. Wired Handset Cable Type Cable Length (m) Standard Optiona

Page 83

www.acson-international.com

Page 84

ASCON Service Guide Book Handset Oper

Comments to this Manuals

No comments